Innovation | Action | Excellence
Flying with Light

distribution配气

PLA-MAC1005 Multi-channel atmosphere controller

PLA-MAC1005多路气氛控制器

Column:配气Brand:PerfectlightViews:596
The PLA-MAC1005 Multi-Channel Atmosphere Controller is designed to work in conjunction with the PCX50 Discover Multi-Channel Photocatalytic Reaction System. It is used for controlling the atmosphere inside the reaction bottles of the multi-channel system
  • Introduction
  • Application
  • Literature
  • Maintenance

The PLA-MAC1005 Multi-Channel Atmosphere Controller is designed to work in conjunction with the PCX50 Discover Multi-Channel Photocatalytic Reaction System. It is used for controlling the atmosphere inside the reaction bottles of the multi-channel system and can also be extended for use in small-volume systems with needle penetration.

The PLA-MAC1005 Multi-Channel Atmosphere Controller, in conjunction with the built-in sensors, can accurately detect and control the gas pressure inside the reaction bottles. This allows for multiple cycles of gas exchange and pressure adjustment within the bottles, maintaining the atmospheric conditions inside at levels below several tens of ppm. Additionally, it can monitor the changes in gas pressure in multiple reaction bottles.

Product Advantages

● Automatically controls multiple gases' pressure inside different reaction bottles based on preset conditions

● Easy-to-use touchscreen operation

● Three operation modes: Independent, Collective, and Measurement, meeting different experimental needs

● Real-time data display and various recording methods

Application Areas            

▲ Particularly Suitable   ● Moderately Suitable  ○ Can Be Used

MCP-WS1000 Photocatalytic Workstation Special Sample Pre-treatment Equipment

▲ Requires precise control of atmosphere and pressure conditions for reactor airtightness testing
 

The PLA-MAC1005 Multi-Channel Atmosphere Controller is connected to the gas source and the reaction bottles. It has a built-in vacuum pump and pressure sensor, allowing for gas replacement and pressure adjustment operations within the reaction bottles. The replacement efficiency is 1 min/bottle, 4 min/9 bottles (physical picture of the reaction bottle shown in Figure 2), maintaining residual gas concentration below several tens of ppm.

Chromatographic results after 6 times of gas replacement by PLA-MAC1005 Multi-Channel Atmosphere Controller in reaction bottles

Figure 1. Chromatographic results after 6 times of gas replacement by PLA-MAC1005 Multi-Channel Atmosphere Controller in reaction bottles

Reaction bottles and caps used with PLA-MAC1005 Multi-Channel Atmosphere Controller

Figure 2. Reaction bottles and caps used with PLA-MAC1005 Multi-Channel Atmosphere Controller

 

The PLA-MAC1005 Multi-Channel Atmosphere Controller has three working modes: Independent, Collective, and Measurement.

In Independent mode, pressure control and pressure regulation are performed separately on 9 reaction bottles. This is suitable for reactions of the same photocatalyst at different CO₂ gas pressures, allowing the selection of the optimal reaction pressure or initial concentration.

In Collective mode, unified pressure control is applied to 9 reaction bottles at the optimal reaction pressure, allowing parallel experiments on pressure atmosphere during the experimental process.

In Measurement mode, pressure changes during the reaction process are monitored and recorded in real-time, providing real-time tracking of the reaction process.

Operation interface of PLA-MAC1005 Multi-Channel Atmosphere Controller - Operation Mode 

Operation interface of PLA-MAC1005 Multi-Channel Atmosphere Controller - Measurement Mode 

Figure 3. Operation interface of PLA-MAC1005 Multi-Channel Atmosphere Controller

 

The PLA-MAC1005 Multi-Channel Atmosphere Controller is easy to operate and user-friendly, featuring a colorful 7-inch multi-touch LCD screen for real-time display (resolution 1024×600). The screen can rotate 360 degrees and comes with a highly sensitive touch pen.

Screen rotation mode of PLA-MAC1005 Multi-Channel Atmosphere Controller

Figure 4. Screen rotation mode of PLA-MAC1005 Multi-Channel Atmosphere Controller

 

Technical Specifications
Operating Voltage 220 VAC/50 Hz
Operating Positions 9 positions
Ultimate Vacuum 4 kPa
Pressure Control Range 10 ~ 400 kPa, Pressure Control Accuracy: ±0.5 kPa
Operating Modes Collective mode, Independent mode, Measurement mode
Collective Mode Can simultaneously select 1 ~ 9 reaction bottles for gas atmosphere replacement and uniform pressure control
Independent Mode Can simultaneously select 1 ~ 9 reaction bottles for gas atmosphere replacement and separate pressure control
Data Display Real-time curve and table display
Adjustable Parameters Vacuum time, Inflation time, Number of cycles
Equipped with a built-in pressure sensor and a colorful 7-inch multi-touch LCD screen for real-time display (resolution 1024×600, 360° rotation, and comes with a highly sensitive touch pen)

Representative Publications

Representative Publication 1
Representative Publication 2